ELECTRIC GENERATOR DIVISION


 
 
 

ABU AMER EQUIPMENT HIRING:


QUALITY SERVICE:
Hiring the best maintained, most reliable Electricity Generators,All our Equipment are the latest models.
COMPLETE: The complete answer to tell your Electricity Generators needs.
SELECTION: The largest Electricity Generators hirer in Bahrain.
COMPETITIVE HIRE RATES: The Best Quality and Hire Rates in Bahrain.
 

ELECTRIC GENERATOR 3-PHASE
 



A) GENERATORS IN SILENCED CANOPY


DIESEL GENERATOR NAME

MAXIMUM PRIME POWER RATING

DIESEL TANK CAPACITY (LITRES)

PRIME RATING DIESEL CONSUMPTION (LITRES / HR)

OPERATING WHIGHT(kg) Dry / Wet

SOUND PRESSURE
LEVEL (dBA) at 100% Load

OVERALL
DIMENSIONS(mm)

Standby
Rating
(kVA)

Maker & Model

kVA

kW

Amps Per Phase

75%

100%

  1 m 7 m Length Width Height

18 kVA

Olympian GEP18-2

16.2

13.2

23.8

45

3.5

4.5

715

81.7

63.4

1684

860

1252

22 kVA

Olympian GEP22

20

16

28.9

45

3.9

5.4

728

78.0

63.7

1684

860

1252

30 kVA

Olympian GEP30-1

27

21.6

39

230

4.8

6.2

1104

79.6

68.2

2090

950

1558

33 kVA

Olympian GEP33-1

30

24

43.3

230

5.7

7.5

1114

80.0

68.7

2090

950

1558

44 kVA

Olympian GEP44

40

32

57.7

245

7.1

9.4

1245

79.7

69.6

2242

1100

1640

50 kVA

Olympian GEP50-5

45

36

65.0

245

7.9

10.6

1245

79.6

69.4

2242

1100

1640

65 kVA

Olympian GEP65-5

60

48

86.6

245

10.3

13.8

1315

82.1

71.2

2242

1100

1640

88 kVA

Olympian GEP88-1

80

64

115.5

245

14.0

18.1

1435

81.4

70.5

2242

1100

1640

110 kVA

Olympian GEP110

100

80

144.3

300

16.9

22.8

1714

81.1

69.5

2805

1100

1610

138 kVA

Atlas Copco QAS138

125

100

180.4

310

20.2

27

2400

 

 

 

 

 

150 kVA

Olympian GEP150

135

108

194.9

375

24.2

31.2

1970

80.1

69.1

3425

1100

1590

165 kVA

Olympian GEP165

150

120

216.5

375

26.4

31.2

1975

80.6

69.5

3425

1100

1790

175 kVA

Olympian GEP175

160

128

230.9

550

28.1

37.5

2797

 

 

3894

1300

1996

220 kVA

Olympian GEH220

200

160

288.7

550

37.4

49.4

2944

75.9

61.0

3894

1300

1996

275 kVA

Olympian GEH275

250

200

360.8

550

46.1

58.9

3094

76.0

61.7

3894

1300

1996

300 kVA

Cummins C300 D5

275

220

396.9

691

42.0

 

4734

77

69

4248

1360

2216

350 kVA

Cummins C350 D5

320

256

461.9

900

52.0

 

4744 / 5576

77

70

5110

1563

2447

400 kVA Cummins C400 D5 360

288

519.6

900

57.0

 

5288

78

71

5110

1563

2447

400 kVA Caterpillar 3406 365

292

526.8

 

59.0

78.4

5430

 

 

 

 

 

550 kVA Cummins C550 D5 500

400

721.7

900

78.7

 

5681/6419

79

72

5110

1563

2447

706 kVA Cummins 565 DFGB (S) 640

512

923.8

 

104.0

 

 

80

75

20’ ISO CONTAINER
825 kVA Cummins 660 DFGD (S) 750

600

1082.5

 

110.0

 

 

80

75

20’ ISO CONTAINER
1110 kVA Cummins 888 DFHD (S) 1000

800

1443.4

 

151.0

 

 

82

77

40’ ISO CONTAINER
1132 kVA Cummins 906 DFJD (S) 1029

823

1485.2

 

161.0

 

 

82

77

40’ ISO CONTAINER

 


 

IMPORTANT NOTES:

1) All Our Generators are in Excellent Working Condition.
2) Generators Names / Sizes are Based on the Manufactures Ratings. (Nameplates) & Show the Maximum Standby Ratings.
3) The generator DRY weight includes Lube Oil, no coolant, no fuel.
4) Most Generator output are designed at 27 degrees C and are subject to 7.5% de-rating at 50 degrees C and 10% at 55 degree C.
5) For Power Calculations We Recommend You to Base Your Maximum Load at 75% of the Prime Power Ratings.
6) All Generators Are Tuned to Bahrain Standard Frequency & Voltage as Follows:
     a) Voltage Line to Line = 400 Volts, Voltage Line to Neutral = 230 Volts
     b) Frequency = 50HZ, Power Factor = 0.8
7) Generators From 44kVA to 810 kVA May be Converted to Other Voltage / Frequency after Prior Arrangement.

8) Generators from 18 TO 375 kVA are all fitted on Detachable Mobile Trailers, to simplify Delivery.

AVAILABLE ACCESSORIES:

4 Core armored cables: 10, 16, 25, 35, 50, 70, 120 mm2 of different lengths: 15, 20, 25, 30, 35 meters long.
Three Phase distribution board.
Manual change over switches: 125, 160, 200, 260, 300 Amps / Phase. This is to allow load transfer from Electricity Directorate to Generator Power.