A) GENERATORS IN SILENCED CANOPY
| Diesel Generator
Name/Size (kva) Standby
Rating |
Maximum
Output (prime Power Rating) |
Operating
WEIGHT (kg) |
Diesel Tank Capacity
(litres) |
Prime
Rating Diesel Consumption (litres/Hr) |
| kVA |
kW |
Amps
Per Phase |
| 75% |
100% |
| 18kVA |
16.2 |
13 |
23.4 |
610 |
45 |
2.9 |
3.8 |
| 22kVA |
20 |
16 |
28.9 |
615 |
45 |
3.0 |
4.3 |
| 30kVA |
27 |
21.6 |
39 |
1095 |
230 |
4.8 |
6.2 |
| 44kVA |
40 |
32 |
57.7 |
1245 |
245 |
8.9 |
11.9 |
| 50kVA |
45 |
36 |
65 |
1245 |
245 |
10.0 |
13.4 |
| 65kVA |
60 |
48 |
86.6 |
1315 |
245 |
11.1 |
14.8 |
| 83kVA |
75 |
60 |
108.2 |
1435 |
245 |
13.9 |
18.6 |
| 110 kVA |
100 |
80 |
144.3 |
1725 |
300 |
17.9 |
23.9 |
| 138kVA |
125 |
100 |
180.4 |
2400 |
310 |
20.2 |
27 |
| 150kVA |
135 |
108 |
194.9 |
2340 |
550 |
21.2 |
28.3 |
| 175kVA |
160 |
128 |
230.9 |
2710 |
550 |
28.1 |
37.5 |
| 220 kVA |
200 |
160 |
288.7 |
2890 |
550 |
32.0 |
42.7 |
| 275 kVA |
250 |
200 |
360.8 |
3080 |
550 |
41.0 |
54.6 |
| 338 kVA |
300 |
240 |
433 |
4800 |
530 |
42.8 |
57 |
| 400 kVA |
365 |
292 |
526.8 |
5430 |
|
59.0 |
78.4 |
| 550 kVA |
500 |
400 |
721.7 |
6000 |
1200 |
78.6 |
102.9 |
| 810kVA |
725 |
580 |
1046.4 |
12500 |
2000 |
130.4 |
171.7 |
B) GENERATORS
IN WEATHERPROOF CANOPY
DIESEL
GENERATOR NAME / SIZE (KVA) STANDBY RATING |
MAXIMUM
OUTPUT (PRIME POWER RATING) |
OPERATING WEIGHT (kg) |
DIESEL TANK CAPACITY (LITRES) |
PRIME
RATING DIESEL CONSUMPTION
(LITRES / HR) |
| kVA |
kW |
AMPS
PER PHASE |
| 75% |
100% |
| 10
kVA |
9 |
7.2 |
13 |
300 |
44 |
1.9 |
2.5 |
| 20 kVA |
18 |
14.4 |
26 |
800 |
60 |
3.0 |
4.3 |
| 44 kVA |
40 |
32 |
57.7 |
1400 |
180 |
8.9 |
11.9 |
| 50 kVA |
45 |
36 |
65 |
1500 |
176 |
10.0 |
13.4 |
75 kVA |
67 |
53.6 |
96.7 |
1600 |
176 |
13.2 |
17.7 |
110 kVA |
100 |
80 |
144.3 |
2000 |
230 |
17.9 |
23.9 |
220 kVA |
200 |
160 |
288 |
3200 |
350 |
32.0 |
42.7 |

IMPORTANT
NOTES:
1) All Our Generators are in Excellent Working Condition.
2) Generators Names / Sizes are Based on the Manufactures Ratings.
(Nameplates) & Show the Maximum Standby Ratings.
3) For Power Calculations We Recommend You to Base Your Maximum
Load at 80% of the Prime Power Ratings.
4) All Generators Are Tuned to Bahrain Standard Frequency &
Voltage as Follows:
Voltage Line to Line = 400 Volts, Voltage Line to Neutral =
230 Volts
Frequency = 50HZ, Power Factor = 0.8
5) Generators From 44kVA to 810 kVA May be Converted to Other Voltage
/ Frequency After Prior Arrangement.
6) Generators From 18 TO 375 kVA are all fitted on Detachable Mobile
Trailers, to simplify Delivery.
AVAILABLE ACCESSORIES:
4 Core armored cables: 10, 16, 25,
35, 50, 70, 120 mm2 of different lengths: 15, 20, 25, 30, 35 meters
long.
Three Phase distribution board.
Manual change over
switches: 125, 160, 200, 260, 300 Amps / Phase. This is to allow
load transfer from Electricity Directorate to Generator Power.